Mobile Digital Radiography System SpecificationÂ
Item |
Specification |
||
1. High voltage generator | |||
1.1 |
standard output power:5.6kW | ||
1.2 |
mA range:10-100mA | ||
1.3 |
Tube voltage range:40-125kV | ||
1.4 |
mAs range :0.1-200mAs | ||
1.5 |
Load time range:0.002s~4s | ||
1.6 |
High voltage transformer structure:The power frequency | ||
2.X-ray tube | |||
2.1 |
Focus range:0.6/1.8mm | ||
2.2 |
Anode types: fixed anode | ||
2.3 |
The maximum voltage:125kV | ||
2.4 |
Anode angle 15° | ||
2.5 |
The inherent filtration:0.6mm Al/75kV | ||
3. Collimator | |||
3.1 |
The inherent filtration:1 mm Al /70 kV; | ||
3.2 |
Collimator is equipped with LED lights(Bright 30S are automatically extinguished) | ||
3.3 |
Collimator is built into measuring ruler | ||
 4. The tube bracket structure | |||
4.1 |
SID: 330 ~ 1650mm | ||
4.2 |
Size after folding:1060*400*400mm | ||
4.3 |
weight:32KG | ||
5. Detector(iRay) | |||
5.1 |
WIFI connection, Amorphous Silicon oxide ,whole panel technology | ||
The effective camera size of the detector:350mm×430mm | |||
5.3 |
Pixel size:150 µm | ||
5.4 |
Gathering matrix:≥2304×2800pixels | ||
5.5 |
Spatial resolution≥3.4lp/mm | ||
5.6 |
Pixel gray level:≥14bit | ||
5.7 |
Detector cooling mode: natural cooling | ||
6. Digital image workstation | |||
6.1 |
CPU frequency:CORE i3 | ||
6.2 |
Memory capacity:4GB | ||
6.3 |
Hard drive capacity:500 GB | ||
6.4 |
64 bit Windows operation system | ||
7. Image acquisition software | |||
7.1 |
Patient registration: acquisition, find the patient data, to prepare for the photography |
||
7.2 |
Images display, image analysis, processing and output |
||
7.3 |
Data management: managing patient data, leading in, leading out , batch file, etc in accordance with DICOM3.0,5.4AH |
||
7.4 |
System diagnosis: monitoring system status, diagnosis of the system fault |
||
8. Battery | |||
8.1.1 |
Power supply way | ||
8.1.2 |
Lithium battery supply | ||
8.1.3 |
The rated capacity:32.4V | ||
8.2 |
Battery capacity: More than 100 exposures, (Exposure conditions:50kV,80mA,20ms ) | ||
8.3 |
Dual power supply, exposure under either wall current or lithium battery | ||
8.4 |
Maximum charging 4 hours | ||
8.5 |
The standby time is not less than 7 hours | ||
8.6 |
Can support hand switch and remote-control exposure | ||
9. The machine parameters | |||
9.1 |
Appearance size | ||
9.1.1 |
Whole machine width:240 mm | ||
9.1.2 |
Whole machine length:440 mm | ||
9.1.3 |
Whole machine height:236 mm | ||
9.2 |
Whole weight (no detector):18kg | ||
10. Options | |||
10.1 |
Wireless network data transmission (WIFI) | ||
10.2 |
Choose a chest rack | ||
10.3 |
The selection of moving flat bed | ||
11. After sale service | |||
11.1 |
The machine warranty 1 year | ||
11.2 |
Provide complete operation manual 1 set | ||
11.3 |
Free service hot line | ||
12. copyright certificate | |||
12.1 |
Utility model: a kind of medical product damping rotation axis | ||
12.2 |
Appearance patent: portable digital X-ray machine | ||
12.3 |
Software copyright: Mayamed technology portable X-ray machine embedded system software |